9 8. Temperature Function (Fahrenheit): Measures tempera-ture in °F. Auto-ranging from -58°F to +752°F. (Optional “K-Type” thermocouple require
10 25. 15A Input Jack. For red test lead probe connection when measuring high DC current (up to 15 amps only). 26. DWELL ANGLE, MS °C, °F, BAT
11 1. Plug the BLACK test lead into "COM" jack of the tester; plug the RED test lead into the "V" jack. NOTE: If alligator c
12 NOTE: A diode is a semiconductor device that lets current flow in one direction only. If the diode to be tested is part of a circuit (with ot
13 E. FREQUENCY MEASUREMENT Frequency is the number of times that an event repeats itself during a one-second time period. Frequency is measured
14 H. TEMPERATURE MEASUREMENT WARNING To avoid fire and/or electrical shock hazards, DO NOT connect the thermocouples to circuits greater than
15 To measure from 0 to 400mA, set the Selector Switch to . To measure from 400mA to 15 Amps DC, set the Selector Switch to the "15A&q
16 WARNING Ignition coils produce a very high voltage. To reduce the risk of electric shock when conducting RPM tests, DO NOT touch the uninsul
17 Do not apply around or remove from Hazardous Live conductors. 1. Turn the ignition off. DO NOT CONNECT THE INDUCTIVE PICKUP WITH THE ENGINE
18 2. Press the HOLD button again to turn the function “off.” The HOLD icon will disappear, and the value will no longer be “locked” in the dis
1 Table of Contents Title Page No. INTRODUCTION ... 2 SAFETY PRECAUTIONS/WARNING
19 For battery replacement: Remove one screw from the battery compartment cover. Use your finger or a small coin to remove the cover. Remove t
20
21
22 LIMITED ONE YEAR WARRANTY The Manufacturer warrants to the original purchaser that this unit is free of defects in materials and workmanship
2 INTRODUCTION Congratulations. You have purchased a precision instrument manufactured to the highest quality standards. This Digital Automot
3 Always inspect the tester, test leads and any other acces-sories for damage prior to every use. If any damage is found, do not use tester un
4 Automatic zero adjustment Over range indicator (except 15 A function). Displays "OL" on LCD Low battery indicator. Displays
5 ACV TRMS [1] NOTE: Specifications are AC-coupled true RMS. Range Resolution Accuracy Overload Protection 400mV 100μV ±(1.2% of reading +8 digi
6 DC CURRENT (AMPS) Range Resolution Accuracy Overload Protection 40mA 10μA 400mA 100μA ±(1.5% of reading +5 digits) 0.5A/250V fast fuse Input
7 TEMPERATURE Range Accuracy Overload Protection 32°F to 104°F (0°C to 40°C) ±5°F/±3°C -58°F to 392°F (-50°C to 200°C) 392°F to 752°F (200°C to 4
8 WARNING Risk of Explosion. This equipment has internal arcing and sparking parts, which should not be exposed to flammable vapors. This equip